4.8 x 12 mm RFID Animal Microchip Tag with Syringe for Pet and Animal Identification
DAFTags 4.8 x 12 mm RFID animal glass microchip tag is supplied with a syringe for pet and animal identification programs in veterinary clinics, shelters, breeding operations, and animal management projects. The tag uses a read/write chip configuration, and frequency and protocol options should be matched to the buyer's reader system.
Available configurations include 125 kHz, 134.2 kHz, and 13.56 MHz options, depending on the selected chip. ISO 11784/11785 and FDX-B options are available for applicable configurations. Confirm the reader model, chip protocol, and required data setup before ordering.
Buyer Pain Points This Product Addresses
- Unstable reads across different reader systems: A chip that does not match the reader or protocol can cause failed reads and repeated scanning. The supplier can confirm the frequency, chip type, and protocol before production.
- Extra handling work before implantation: Buying the tag and injector separately creates more preparation steps and increases the chance of using mismatched components. This product is supplied with a syringe.
- Inconsistent batch supply: Shelters, veterinary networks, distributors, and animal ID projects need repeatable dimensions and packaging. A defined 4.8 x 12 mm format and pre-order specification review help reduce unnecessary quality checks.
- Limited documentation for procurement approval: Purchasing teams need clear technical information before approving a microchip supplier. Frequency, protocol, syringe material, packaging, sterilization, and storage details can be reviewed before shipment.
What Is This RFID Glass Animal Microchip Kit?
This product combines a glass-encapsulated RFID tag with a syringe for animal identification. The 4.8 x 12 mm glass tag is designed for applications where staff need a compact readable ID that can be connected to animal records.
The tag uses a read/write chip configuration. Depending on the selected version, the product supports 125 kHz, 134.2 kHz, or 13.56 MHz operation, with ISO 11784/11785 and FDX-B options available for applicable configurations.
![]() |
Main Features: 1. Unique identity for every livestock and pet. 2. Import and export control. 3. Lost pet can be easily traced back to it's owner. 4. Veterinarians are able to keep the animal's heath record. 5. Easily implanted and no impact on the animal. 6. Suitable for use in extreme conditions. 7. Coupled with software, the RFID tag is a must in management of animals, either livestock or household pet.
|
![]() |
|
Applications
- Veterinary clinics and animal hospitals
- Animal shelters and rescue organizations
- Pet microchip distributors
- Breeders and pet-care networks
- Animal registration and identification programs
- RFID system integrators and project suppliers
Compatibility Note
Before ordering, send the following information so the correct configuration can be confirmed:
- RFID reader model or reader frequency
- Required chip protocol
- Read-only or read/write requirement
- Target animal application
- Required tag size and project quantity
The supplier can then confirm the suitable configuration before sampling or mass production.
Procurement and Compliance Review
Some claims on the original product listing should be supported by current documentation before being published as firm specifications:
- Applicable certification or registration documents, including ICAR
- ISO 11784/11785 and FDX-B compliance for the selected configuration
- Whether the stated read range applies to the 4.8 x 12 mm version
- Sterilization validation and packaging shelf-life documentation
- Whether bio-glass, antibacterial, or anti-allergy claims are supported by test reports
- Available MOQ, sample policy, lead time, and customization scope
FAQ
Will this tag work with our existing RFID reader?
Compatibility depends on the reader frequency, chip type, protocol, and software system. Share your reader model or required protocol so the configuration can be checked before ordering.
Is the syringe included?
Yes. This product is supplied with a syringe. The listed syringe material is polypropylene, and the syringe is supplied in a medical-grade sterilization pouch with EO gas sterilization.
Can the tag size or frequency be customized?
Several sizes and frequency options are listed. Confirm the required size, frequency, protocol, and quantity so the available configuration can be checked.
Is the tag read-only or rewritable?
The listed chip type is read/write. The exact memory and writing function depend on the selected chip configuration and should be confirmed before production.
What is the reading distance?
The listed read range is 20-50 mm. Actual performance depends on the reader, antenna, tag orientation, surrounding materials, and operating conditions.
Can you provide samples before a bulk order?
Request a sample with your reader information and application details. This allows compatibility and handling requirements to be reviewed before a larger purchase.
Request a Quote
Send your reader model, required frequency, protocol, tag size, and quantity. The supplier will confirm the suitable configuration and provide the next step for sampling or bulk production.
Request a Quote | Request a Sample
Tel : +86 15814022871
Email : sales@daftag.com


















